SIEMENS - N 501/01 - Combinatie zonnewerings actuator KNX, 4 x AC 230 V, 6 A, 8 x binary i - 5WG15011AB01

SIEMENS
KopiërenKopiëren
SIEMENS - N 501/01 - Combinatie zonnewerings actuator KNX, 4 x AC 230 V, 6 A, 8 x binary i

Log in of maak een account aan om de prijs- en bestelinformatie te bekijken

Belangrijke informatie

  • Bussysteem KNX - ja

  • Montagewijze - DRA (DIN-rail adapter)

  • Aantal ingangen - 8

  • Andere bussystemen - Zonder

  • Max. schakelvermogen - 1380 W

Verpakkingsinfo

  • 1 stuk(s)

  • Niet retourneerbaar product

EAN

4001869377551

Ref Cebeo

5WG15011AB01

Ref leverancier

5WG15011AB01

Ref commercieel

5WG1501-1AB01

Bussysteem KNX:

ja

Montagewijze:

DRA (DIN-rail adapter)

Aantal ingangen:

8

Andere bussystemen:

Zonder

Max. schakelvermogen:

1380 W

Bussysteem KNX-RF (radiofrequent):

nee

Bussysteem radiofrequent:

nee

Bussysteem LON:

nee

Bussysteem Powerline:

nee

Radiofrequent bidirectioneel:

nee

Breedte in module-eenheden:

8

Busaansluiting inclusief:

ja

Busmodule afneembaar:

nee

Manuele bediening:

ja

Met LED indicatie:

ja

Schakelstroom ohms:

6 A

Max. aantal jaloezie-uitgangen:

4

Met schakelfunctie:

nee

Type stroom:

AC

Beschermingsgraad (IP):

IP20

Siemens 5WG1501-1AB01
Combinatie zonnewerings actuator KNX, 4 x AC 230 V, 6 A, 8 x binary inputs

Artikelnummer: N 501/01
EAN code: 4001869377551
Recupel code: -
Batterij bijgeleverd: -

Aanvullende/Extra/Uitgebreidere informatie:
- 8 inputs for DC or AC in the range from 12 to 230 V - 8 relay contact outputs locked in pairs against each other for controlling 4 × AC 230 V sunblind drives - Contact rated voltage AC 230 V - Contact rated current 6 A, p.f. = 1 - Electronics powered by a AC 230 V integrated power supply - Device functional even without bus connection or if the bus communication fails - Preset on delivery for direct output control for each blind button function via momentary contact switches connected to the inputs - Key for switching between bus and direct mode - Button for each relay contact output, for switching the output in direct mode - Selectable function for each input when using the ETS: - Switching status, send binary value - Switching on leading edge, switching Short/Long - 1-pushbutton dimming, sunblind control, group control - 1-bit/8-bit scene control - 8-bit/16-bit value leading edge, Short/Long - 16-bit floating point value leading edge, Short/Long - Or for each pair of inputs: - Acting directly on the corresponding outputs as blind button - 2-button dimming with stop telegram or with cyclical sending - 2-pushbutton sunblind control - Selectable blocking of each input via a corresponding blocking object - Sending of input objects after change - Selectable cyclical input object sending - Individual or shared configuration of actuator channels - Communication objects for each blind channel for driving the sun protection into the end positions or for stopping the procedure and adjusting the blind slats in steps - Communication objects for setting position of slats and blinds in percentage information - Automatic opening of the blind slats to a preconfigured nominal setting after uninterrupted driving down of the blind from the top to the bottom end position, with integrated 1-bit scene control for storing and calling up (reproduction) of 2 interim blind and slat settings - Integrated 1-bit/8-bit scene control, 8 scenes can be integrated per channel - Optional Sun object for integration in a sunlight tracking control system - Differentiation between automatic and manual mode and with automatic switchover from automatic to manual mode for the channel in question by pressing a bus button for manual control of the corresponding sun protection - Manual mode taking precedence over automatic position commands - Optional central command for each device or each channel for switching the relevant channels to automatic mode and driving the sun protection into the up or down end position - Alarm: move to safety position, Locking in this position for as long as alarm is active - Travel lock (e. g. for cleaning the outer shutter/blinds) - Status objects for each channel for querying or for automatic sending of sun protection and slat settings as a percentage value - Optional status objects for reporting that the up or down position has been reached - Integrated bus coupling unit, Bus connection via bus terminal or contact system to data rail - Modular installation devices for mounting on TH35 EN 60715 mounting rail