WEIDMUELLER - Customer specific product PV 210S0F3CXXV1O0TXPX10PWW - 8000111135

WEIDMUELLER
KopiërenKopiëren
WEIDMUELLER - Customer specific product PV 210S0F3CXXV1O0TXPX10PWW

Log in of maak een account aan om de prijs- en bestelinformatie te bekijken

Belangrijke informatie

  • Breedte - 636 mm

  • String beveiliging - 2-polig

  • Hoogte - 847 mm

  • Diepte - 300 mm

  • Voor zekeringsgrootte - 10x38mm

Verpakkingsinfo

  • 1 stuk(s)

  • Niet retourneerbaar product

EAN

4099986935648

Ref Cebeo

8000111135

Ref leverancier

8000111135

Ref commercieel

PV 210S0F3CXXV1O0TXPX10PWW

Breedte:

636 mm

String beveiliging:

2-polig

Hoogte:

847 mm

Diepte:

300 mm

Voor zekeringsgrootte:

10x38mm

Maximale ingangsspanning DC:

1000 V

Aantal ondersteunde MPP trackers:

1

Materiaal:

Kunststof

Beschermingsgraad (IP):

IP65

Slagvastheid:

IK10

Type zekering:

gPV (Full-range Fotovoltaïsche bescherming)

Testklasse type 1:

ja

Testklasse type 2:

ja

Testklasse type 3:

nee

Gebruikstemperatuur:

-20...45 °C

Max. uitgangsstroom:

0 A

Kleur:

Wit

Maximale ingangsstroom per string:

30 A

Aantal leidinginvoeringen:

10

Type invoer:

Wartel

Voorzien van lastscheider:

ja

Aansluitwijze:

Steekklem

Combiner box for inverters with Fireman switch and surge protection for the connection to 1 MPP tracker. Suitable for remote disconnection of the DC side by the fire department according to VDE-AR-E2100-712. Max. string voltage Uoc: 1000 VDC Integrated surge protection with class I+II combined arresters with signal contact. Suitable for protection against overvoltages in a photovoltaic system according to DIN CLC/TS 51643-32. MPP1: 10 inputs, connection via M25 cable gland with multiple sealing inserts. PUSH IN connection / single-wire, multi-wire, with/without ferrule. 1 output, connection via M25 cable gland with multiple sealing inserts. PUSH IN connection / single-wire, multi-wire, with/without ferrule. DC fireman switch: Switching off by undervoltage triping. Switching off by reaching a temperature of >= 100 °C in the housing. Automatic reconnection after the control voltage (230 V AC) is applied again. With signal contact. Connection of the fireman switch control line 230 VAC via M16 cable glands (Clamping range 5-10 mmØ) max. conductor cross-section: 1.5 mm². Connection of the signal contact 24 VDC (max. 300 mA) via M16 cable glands (Clamping range 5-10 mmØ) max. conductor cross-section: 1.5 mm². Protection class: IP65. All built into a glas fibre reinforced polyester housing. Dimensions HxWxD: 847x636x300 mm. Approval according to low voltage switchgear IEC 61439-1 and EN 61439-2